40 | SOL 25 PLUS WWW.STIEBEL-ELTRON-USA.COM
5.3 Flush Mounting On A Pitched Roof
Stiebel Eltron provides flush-mounting kits for both vertical and
horizontal collector layouts, part numbers SFM001 and SFM001H,
respectively. Figure 24 shows the SFM001 kit and Figure 25 shows
the SFM001H kit. Stiebel Eltron flush mount kits are generally not
recommended for mounting upon flat roofs, walls, or the ground.
Instead, the 45° or 30/60° mounting systems are more appropriate
for mounting to structures other than pitched roofs.
Figure 24: Vertical Flush Mount Kit (p/n SFM001).
M10 nuts
M10 bolts
Support Rail (S201)
Mounting L-bracket (S102)
M10 nuts
M10 bolts
Support Rail (S101)
Mounting L-bracket (S102)
24
25
The collector mounting frames (p/n 185545 and/or 185546) may be
used as templates for locating the support rails and L-brackets. The
locations of fasteners may be determined from these templates.
After the mounting L-brackets are installed, assemble the frame
profile rails to the support rails (S101) with the included fasteners,
then bolt the assembly to the L-brackets.
Figure 25: Horizontal Flush Mount Kit (p/n SFM001H).
5.3.1 Detailed Assembly Instructions for Flush Mounting Kit
Step 01: Major components for assembly of
the Stiebel Eltron flush mounting kit (single
panel vertical version displayed).